Hi !
I had 2 Problems (running Win 8.1):
First: it only charged when OFF, not when windows booted.
Then: NO Charge at all after playing with a USB Hub (nothing defective, just unplugging and replugging).
I solved the NO CHARGE Problem this way:
I opened it, unsoldered the battery (easy, 3 wired, PLEASE isolate them, do NOT short the wires).
Then i sortened (bridged) the 3 solder "blobs" on the PCB with each other to drain remaining capacity from the "confused" charger chip i wanted to reset.
Then resolder battery, BAM, it works again.
My first problem remains --> only charging when OFF, but as i now have an AMpere meter conneted all the time i guess i have the solution !
My battery profile has a low brightness, my "powered" has a high brightness. So if the X98 detects the charger it starts charging (i can see around 1 Amp flowing) and turns up the brightness. BUT the bright screen drains so much power that the Voltage drops and the charging circuit senses that and thinks chargin is over and stops charging.
If you have around 75% brightness this goes on & off forever, my Ampere meter jumping between 1 Amp and 0 Amp all the time, brightness going up and down.
Solution (Well workaround): Set the "powered" brigthness to a low value and ENJOY charging.
Maybe Teclast can solve that via Firmware. If they care...
Greetings,
Nils
P.S. if that helps or you have a better Solution, PLEASE post here so we can see if that is just me or if this is a general situation !!!
I had 2 Problems (running Win 8.1):
First: it only charged when OFF, not when windows booted.
Then: NO Charge at all after playing with a USB Hub (nothing defective, just unplugging and replugging).
I solved the NO CHARGE Problem this way:
I opened it, unsoldered the battery (easy, 3 wired, PLEASE isolate them, do NOT short the wires).
Then i sortened (bridged) the 3 solder "blobs" on the PCB with each other to drain remaining capacity from the "confused" charger chip i wanted to reset.
Then resolder battery, BAM, it works again.
My first problem remains --> only charging when OFF, but as i now have an AMpere meter conneted all the time i guess i have the solution !
My battery profile has a low brightness, my "powered" has a high brightness. So if the X98 detects the charger it starts charging (i can see around 1 Amp flowing) and turns up the brightness. BUT the bright screen drains so much power that the Voltage drops and the charging circuit senses that and thinks chargin is over and stops charging.
If you have around 75% brightness this goes on & off forever, my Ampere meter jumping between 1 Amp and 0 Amp all the time, brightness going up and down.
Solution (Well workaround): Set the "powered" brigthness to a low value and ENJOY charging.
Maybe Teclast can solve that via Firmware. If they care...
Greetings,
Nils
P.S. if that helps or you have a better Solution, PLEASE post here so we can see if that is just me or if this is a general situation !!!
Aucun commentaire: